Wooden Floor - BHB

Sound insulation dry screed PhoneStar - one board one system

For a Brettstapeldecke, refer to the table below (10 floor constructional systems with Phonestar).
These are sorted by the building height, with sound insulation values before and after, technical system data and the shared covering displayed graphically.

 

 

 

 

Brettstapeldecke

BHB BodenHolzBrettstapel (FloorWoodBrettstapel)

Output value impact sound L'n,w,R=76 dB

Output value airborne sound R'w,R=42 dB

The figures above are shown with PhoneStar improved efficiency.

The specified panel thickness are calculated without the final covering. 

Please consider the notes at the end of this chapter.

Impact and airborne sound insulation - BHB

If you want more construction details, click on the favoured floor (e.g. BHB 1.1).

Installation in mm

BHB

Floor Layers

 

PhoneStar Twin

PhoneStar TRI

Wood fibre

Discharge

Airborne sound insulation** R'w,R

Impact sound ** L'n,w,R ∆Lw,R

Announce- ments

Click on the text


10 mm

BHB 1.1

PhoneStar Twin

47 dB

∆=5 dB

70 dB

∆=6 dB


15 mm

BHB 1.2

PhoneStar Tri

49 dB

∆=7 dB

68 dB

∆=8 dB


29 mm

BHB 1.3

PhoneStar Twin

Wood fibre*

48 dB

∆=6 dB

67 dB

∆=9 dB


34 mm

BHB 1.4

PhoneStar Tri

Wood fibre*

50 dB

∆=8 dB

65 dB

∆=11 dB


39 mm

BHB 1.5

PhoneStar Twin

PhoneStar Twin

Wood fibre*

53 dB

∆=11 dB

64 dB

∆=12 dB


49 mm

BHB1.6

PhoneStar Tri

PhoneStar Tri

Wood fibre*

54 dB

∆=12 dB

61 dB

∆=15 dB


59 mm

BHB 1.7

PhoneStar Twin

Wood fibre

Discharge

55 dB

∆=13 dB

56 dB

∆=20 dB


64 mm

BHB1.8

PhoneStar Tri

Wood fibre

Discharge

57 dB

∆=15 dB

54 dB

∆=22 dB


69 mm

BHB 1.9

PhoneStar Twin

PhoneStar Twin

Wood fibre

Discharge

58 dB

∆=16 dB

53 dB

∆=23 dB


79 mm

BHB 1.10

PhoneStar Tri

PhoneStar Tri

Wood fibre

Discharge

61 dB

∆=19 dB

50 dB

∆=26 dB


*   To save installation height (approx. 16 mm), the Holzweichfaser is replaced by the Wolf Protection  

     Fleece. Please contact us if necessary.

 

**  Please note the following information for the given sound insulation datas and other technical

    specifications.

 

Note:

If there are high airborne sound insulation datas of the construction and low impact sound pressure levels which are measured in the underneath room, the sound insulation will be better.

(Encouragement by "Normhammerwerk").

Upgrading impact and airborne sound insulation