PhoneStar massive floor systems (BM)

Please select one of the final ten options


1. PhoneStar directly on massive floor


Illustration

BM 1.1

BM 1.2

Construction Elements

 

Top Layer

PhoneStar TWIN 10 mm

Massive Floor

 

Top Layer

PhoneStar TRI 15 mm

Massive Floor

Construction Height (in mm)

10 mm

15 mm

Impact Sound Insulation

L'n,w,R und ∆Lw,R

54

∆=19dB

51dB

∆=22dB


2. PhoneStar TWIN with woodfiber


Illustration

BM 1.3

BM 1.5

Construction Elements

 

Top Layer

PhoneStar TWIN 10 mm

Woodfiber 19 mm

Massive Floor

 

Top Layer

PhoneStar TWIN 10 mm

PhoneStar TWIN 10 mm

Woodfiber 19 mm

Massive Floor

Construction Height (in mm)

29 mm

34 mm

Impact Sound Insulation

L'n,w,R und ∆Lw,R

50

∆=23 dB

47 dB

∆=26 dB


3. PhoneStar TRI with Woodfiber


Illustration

BM 1.4

BM 1.6

Construction Elements

 

Top Layer

PhoneStar TRI 15 mm

Woodfiber 19 mm

Massive Floor

 

Top Layer

PhoneStar TRI 15 mm

PhoneStar TRI 15 mm

Woodfiber 19 mm

Massive Floor

Construction Height (in mm)

39 mm

49 mm

Impact Sound Insulation

L'n,w,R und ∆Lw,R

48

∆=25 dB

44 dB

∆=29 dB


4. PhoneStar on bonded levelling compound


Illustration

BM 1.7

 

 

BM 1.8

Construction Elements

 

Top Layer

PhoneStar TWIN 15 mm

Woodfiber 19 mm

Bonded Levelling Compound 30mm

Massive Floor

 

Top Layer

PhoneStar TRI 15 mm

Woodfiber 19 mm

Bonded Levelling Compound 30mm

Massive Floor

Construction Height (in mm)

59 mm

64 mm

Impact Sound Insulation

L'n,w,R und ∆Lw,R

47

∆=26 dB

46 dB

∆=27 dB


5. PhoneStar double-layered on bonded levelling compound


Illustration

BM 1.9

 

 

 

 

 

 

 

BM 1.10

Construction Elements

 

Top Layer

PhoneStar TWIN 15 mm

PhoneStar TWIN 15 mm

Woodfiber 19 mm

Bonded Levelling Compound 30mm

Massive Floor

 

Top Layer

PhoneStar TRI 15 mm

PhoneStar TRI 15 mm

Woodfiber 19 mm

Bonded Levelling Compound 30mm

Massive Floor

Construction Height (in mm)

69 mm

79 mm

Impact Sound Insulation

L'n,w,R und ∆Lw,R

45

∆=28 dB

42 dB

∆=31 dB